{"id":259,"date":"2017-07-03T10:10:16","date_gmt":"2017-07-03T10:10:16","guid":{"rendered":"http:\/\/nabytek-levny.eu\/?page_id=259"},"modified":"2021-01-25T10:27:37","modified_gmt":"2021-01-25T10:27:37","slug":"pevna-nastavba-cak-2","status":"publish","type":"page","link":"http:\/\/fabok.cz\/en\/nastavby\/vysokotlake-cistici-nastavby\/pevna-nastavba-cak-2\/","title":{"rendered":"Fixed unit CAK 2"},"content":{"rendered":"<h2>Fixed unit for high pressure sewage cleaning CAK 2<\/h2>\n<p>The tank, wiring and all technology is housed in an insulated bodywork made of 40 mm PUR panels. The bodywork is equipped with independent heating for year-round operation.<\/p>\n<h3><strong>Water tank \u2013 air volume approx. 2 000 l:<\/strong><\/h3>\n<ul>\n<li>plastic \/event. Stainless steel\/<\/li>\n<li>filling connection C-coupling accessible from the side of the structure<\/li>\n<li>with overflow as overfill protection<\/li>\n<li>filling height indicator<\/li>\n<li>inspection manhole in upper part of the tank<\/li>\n<li>easy to clean water filter for filling<\/li>\n<\/ul>\n<h3><strong>High pressure pump: <em>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<\/em><\/strong><\/h3>\n<ul>\n<li>working pressure max.150 bar<\/li>\n<li>pumped amount 61 l\/min.<\/li>\n<li>safety and control valve 0 \u2013 MAX<\/li>\n<li>fine high-volume filter at the inlet to the pump<\/li>\n<li>glycerin manometer for operating pressure control<\/li>\n<li>auxiliary gearbox drive<\/li>\n<\/ul>\n<h3><strong>Double hydraulic hose drum:<\/strong><\/h3>\n<ul>\n<li>hydraulically driven, with stepless speed control in both directions<\/li>\n<li>with automatic hose guidance<\/li>\n<li>capacity for\n<ul>\n<li>80 m pressure hose DN 3\/4\u201c<\/li>\n<li>50 m pressure hose DN 3\/8\u201c<\/li>\n<\/ul>\n<\/li>\n<li>the winch is hydraulically extendable above the sewer shaft + rotating guide roller<\/li>\n<\/ul>\n<h3><strong>Control panel:<\/strong><\/h3>\n<ul>\n<li>non-pressure circulation \u2013 BYPASS<\/li>\n<li>glycerin manometer<\/li>\n<li>HP pump pressure regulation<\/li>\n<li>optical and acoustic signalization of water level<\/li>\n<li>independent heating control<\/li>\n<li>hydraulic winch wind \/ unwind<\/li>\n<li>winch speed continuously adjustable<\/li>\n<li>working light<\/li>\n<li>socket for portable working light<\/li>\n<li>high pressure MTH counter<\/li>\n<li>button TOTAL STOP<\/li>\n<\/ul>\n<h3><strong>Standard accessories:<\/strong><\/h3>\n<ul>\n<li>LED flash lights in the rear part of the superstructure<\/li>\n<li>Hook wrench for \u201eC\u201c coupling<\/li>\n<li>fasteners for pickaxe and shovel<\/li>\n<li>working light on the rear superstructure part<\/li>\n<li>working reflector incl.\u00a015 m cable<\/li>\n<li>independent heating<\/li>\n<li>3\/8\u201c and \u00be\u201c cleaning nozzle<\/li>\n<li>3\/8\u201c and \u00be\u201c pointed nozzle with front jet<\/li>\n<li>high pressure gun with flat and round nozzle<\/li>\n<li>storage space for tools, nozzles and protective equipment<\/li>\n<li>filling fire hose \u201eC\u201c 10 m<\/li>\n<\/ul>\n<h3><strong>Colour design:<\/strong><\/h3>\n<ul>\n<li>blue superstructure according to RAL<\/li>\n<\/ul>\n<h3><strong>Documents:<\/strong><\/h3>\n<ul>\n<li>operating and maintenance instructions of the structure<\/li>\n<li>operating and maintenance instructions of the HP pump<\/li>\n<li>declaration of conformity<\/li>\n<li>certified copy of the approval of the fixed superstructure type<\/li>\n<\/ul>\n<h3><strong>Winter measures up \u2013 20 \u00baC:<\/strong><\/h3>\n<ul>\n<li>high pressure part fittings and hoses draining<\/li>\n<li>insulation of all structure parts \u2013 machines, tanks, drums<\/li>\n<li>independent heating located in the rear part of the structure<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Fixed unit for high pressure sewage cleaning CAK 2 The tank, wiring and all technology is housed in an insulated bodywork made of 40 mm PUR panels. The bodywork is equipped with independent heating for year-round operation. Water tank \u2013 air volume approx. 2 000 l: plastic \/event. Stainless steel\/ filling connection C-coupling accessible from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":35,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/pages\/259"}],"collection":[{"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/comments?post=259"}],"version-history":[{"count":4,"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/pages\/259\/revisions"}],"predecessor-version":[{"id":939,"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/pages\/259\/revisions\/939"}],"up":[{"embeddable":true,"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/pages\/35"}],"wp:attachment":[{"href":"http:\/\/fabok.cz\/en\/wp-json\/wp\/v2\/media?parent=259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}